ring

Syntax
ring ring-id node-mode { { master | transit } [ primary-port interface-type interface-number ]
[ secondary-port interface-type interface-number ] level level-value | { edge | assistant-edge }
[ edge-port interface-type interface-number ] }
undo ring ring-id
View
RRPP domain view
Default level
2: System level
Parameters
ring-id: RRPP ring ID, which ranges from 1 to 64.
master: Specifies the device as the master node of the RRPP ring.
transit: Specifies the device as the transit node of the RRPP ring.
primary-port: Specifies the port as a primary port.
interface-type interface-number: Specifies a port by its type and number. The port can be a Layer-2
Ethernet port or Layer-2 aggregate interface.
secondary-port: Specifies the port as a secondary port.
level-value: RRPP ring level, with 0 representing primary ring and 1 representing subring.
edge: Specifies the device as the edge node of the RRPP ring.
assistant-edge: Specifies the device as the assistant edge node of the RRPP ring.
edge-port: Specifies the edge port for the node.
Description
Use ring to configure the node mode of the device, the role of the specified RRPP port, and the level of
the RRPP ring.
Use undo ring to remove the configuration.
The ID of an RRPP ring in a domain must be unique.
When an RRPP is enabled, you cannot configure its RRPP ports.
When configuring the edge node and the assistant-edge node, first configure the primary ring, and then
the subrings.
The node mode, RRPP port role, and ring level settings of an RRPP ring cannot be modified once they are
configured. To modify the settings, first remove the present settings.
You must remove all subring configurations before deleting the primary ring configuration of the edge
node or the assistant-edge node. However, an active RRPP ring cannot be deleted.
Related command: ring enable.
Examples
# Specify the device as the master node of primary ring 10 in RRPP domain 1, GigabitEthernet 1/0/1
as the primary port and GigabitEthernet 1/0/2 as the secondary port.
70