By default, the errored frame period event triggering threshold is 1.
Related commands: oam errored-frame-period period, display oam link-event, and display oam
configuration.
Examples
# Set the errored frame period event triggering threshold to 100.
<Sysname> system-view
[Sysname] oam errored-frame-period threshold 100

oam errored-frame-seconds period

Syntax
oam errored-frame-seconds period period-value
undo oam errored-frame-seconds period
View
System view
Default level
2: System level
Parameters
period-value: Errored frame seconds event detection interval, ranging from 10 to 900 (in seconds).
Description
Use the oam errored-frame-seconds period command to set the errored frame seconds event detection
interval.
Use the undo oam errored-frame-seconds period command to restore the default.
By default, the errored frame seconds event detection interval is 60 seconds.
Related commands: oam errored-frame-seconds threshold, display oam link-event, and display oam
configuration.
Examples
# Set the errored frame seconds event detection interval to 100 seconds.
<Sysname> system-view
[Sysname] oam errored-frame-seconds period 100

oam errored-frame-seconds threshold

Syntax
oam errored-frame-seconds threshold threshold-value
undo oam errored-frame-seconds threshold