Oam Errored-Frame-Period Window; Oam Errored-Frame-Seconds Threshold - HP 6125XLG Command Reference Manual

Blade switch high availability command reference
Table of Contents

Advertisement

display oam link-event
oam global errored-frame-period threshold

oam errored-frame-period window

Use oam errored-frame-period window to set the errored frame period event detection window.
Use undo oam errored-frame-period window to restore the default.
Syntax
oam errored-frame-period window window-value
undo oam errored-frame-period window
Default
The port uses the global setting.
Views
Ethernet interface view
Predefined user roles
network-admin
Parameters
window-value: Specifies the errored frame period event detection window in the range of 1 to 65535.
The value of this argument must be a multiple of 10000.
Usage guidelines
The configuration in interface view takes effect on the specified port. For a port, the configuration in
interface view takes precedence.
Examples
# Set the errored frame period event detection window to 20000000.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/1/5
[Sysname-Ten-GigabitEthernet1/1/5] oam errored-frame-period window 2000
Related commands
display oam configuration
display oam link-event
oam global errored-frame-period window

oam errored-frame-seconds threshold

Use oam errored-frame-seconds threshold to set the errored frame seconds event triggering threshold on
a port.
Use undo oam errored-frame-seconds threshold to restore the default.
Syntax
oam errored-frame-seconds threshold threshold-value
undo oam errored-frame-seconds threshold
13