In system view, use the flow-interval command to set the statistics polling interval for all interfaces.
In Ethernet interface view, use the flow-interval command to set the statistics polling interval for the
interface.
Examples
# Set the statistics polling interval to 100 seconds on GigabitEthernet 1/0/1.
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1] flow-interval 100
interface
Syntax
interface interface-type interface-number
View
System view
Default level
2: System level
Parameters
interface-type interface-number: Specifies an interface type and number.
Description
Use interface to enter interface view.
Examples
# Enter GigabitEthernet 1/0/1 interface view (assuming that the interface is an Ethernet interface).
<Sysname> system-view
[Sysname] interface gigabitethernet 1/0/1
[Sysname-GigabitEthernet1/0/1]
jumboframe enable
Syntax
jumboframe enable [ value ]
undo jumboframe enable
View
Ethernet interface view
Default level
2: System level
Parameters
value: Sets the maximum length of Ethernet frames that are allowed to pass through, ranging from 1536
to 9216 bytes. If you set the value argument multiple times, the latest configuration takes effect.