DS7200V2-EXP | Installation Guide | 1. Introduction
1.4.7
Alarm Event Memory
The system uses alarm event memory to store
alarm events for each area. You can view the area
alarm events at a keypad assigned to the area.
The control panel clears the area's alarm event
memory and starts storing new alarm events
when you arm the area. Alarm events are
permanently stored in the control panel's history
log.
1.4.8
History Log
The system stores 254 events from all areas in its
event log.
Events can be stored even if the control panel
does not send a report for them. You can view
the log at a text keypad, print it locally using the
DX4010i/DX4010 RS-232 Serial Interface Module
and a serial printer, or upload it to the Remote
Programming Software (RPS).
1.4.9
Wireless (RF) Devices
The control panel supports a variety of wireless
sensor devices, which can be included in the 40-
zone maximum.
1.5

Control Panel Assembly

You should receive the following parts:
Documentation Pack
DS7200V2 Installation Guide (this document)
(P/N: 4998153893)
DS7200V2 Expert Programming Guide
(P/N: 4998153891)
System Worksheet (P/N: 4998153887)
Release Notes (P/N: 4998153890)
User's Guide (P/N: 4998153894)
Assembly
Control Panel Assembly
Red Battery Lead (P/N: 47720B)
Black Battery Lead (P/N: 47721B)
2.2 k EOL Resistors (16 total)
3.65 k EOL Resistors (8 total)
Tamper Switches
1.6

Listings and Approvals

C
This product fulfills the requirements of
EN 50131-1, 50131-2, CLC/TS 50131-3
Bosch Security Systems, Inc. | 04/12 | F01U253045-02
1.7

System Options

1.7.1
Arming Devices
DS7445i LED Keypad: LED keypad that
displays up to 16 zones.
DS7445V2 LED Keypad: LED keypad in new
faceplate design.
DS7447E LCD (Text) Keypad: Text keypad
that displays system information and
programmable text.
DS7447V2 LCD (Text) Keypad: Text keypad
in new faceplate design.
Door Access Control Module (DACM): The
DACM grants or restricts access to a door
using a keypad/credential reader, a Request
to Exit (REX) input, and/or a door contact.
Each DACM supervises one door.
1.7.2
Data Bus Devices
DX2010 Input Expander: Provides 8
additional input loops. The DS7240V2
supports up to 5 modules; the DS7220V2
supports up to 3 modules. Also available:
DX2014 (DX2010 with AE20 ABS plastic
enclosure).
DX3010 Octo-Output Expander: Provides 8
independent, programmable Form "C" relay
outputs. The DS7240V2 supports up to 2
modules; the DS7220V2 supports 1 module.
DX3020 Module: The DX3020 is an X-10
Interface Module. It can emulate up to 2
DX3010 Octo-Output Expanders. One allowed
per system.
DX4010i RS-232 Serial Interface Module:
DTE RS-232 serial interface module that
provides a connection point to the system for
serial devices such as a printer. Can also be
used to create a remote programming direct
connection with RPS. It does not occupy a
control panel address when used this way.
One allowed per system
DX4010 RS-232 Serial Interface Module:
Provides a connection point to the system for
serial devices such as a printer. Can also be
used to create a remote programming direct
connection with RPS. It does not occupy a
panel address when used this way. One
allowed per system.
DX4020 Network Interface Module:
Provides bi-directional communication over
an Ethernet network. Can also be used for
remote programming sessions with RPS. One
allowed per system. Firmware revision 2.10
or greater is required to use the DX4020.