Command 963 - Copy The Programming Key To The Control Panel; Command 999 - Display The Software Version Number; Default The Control Panel With The Hardware - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
6.24
Command 963 – Copy the programming key to the control
panel
This command copies data from the programming key to the control panel.
To copy the programming key to the control panel:
1.
2.
3.
4.
5.
CAUTION!
Failing to exit from Installer's Programming Mode before removing the programming key
cancorrupt the programming key.
6.25
Command 999 – Display the software version number
The version structure is: Vx.xx. This command displays the panel software version.
1.
2.
Display example: For the version 3.17
Enter [9 9 9 #] under the programming mode.
The keypad displays 1st number 3; and press [*] to display the 2nd number 1; then press [*]
to display the 3rd number 7.
Continue to press [*] and no version number will be displayed.
Enter [9 5 9 #] or [9 6 0 #] to exit from Installer's Programming Mode.
The STAY and the AWAY indicators are extinguished on the keypad to indicate that the system
is disarmed.
6.26

Default the control panel with the hardware

If the installer code is lost, the default pads on PCB is used to default the control panel.
1.
2.
3.
4.
5.
6.
CAUTION!
Only the installer code is defaulted, other parameters are not defaulted.
Bosch Sicherheitssysteme GmbH
Enter the installer code (the default is 1234 + 958) and press [#] to enter into installer's
programming mode. Two beeps sound and the STAY and AWAY indicators flash on the
remote keypad to indicate that you have entered into Installer's Programming Mode. The
keypad displays the data stored in Location 000.
Connect the programming key to the PROGRAMMING KEY pins at the top of the control
panel's PCB.
Enter [9 6 3 #]. Two beeps after programming key data is successfully copied to the
control panel. A long beep indicates that the programming key is corrupt and must be
reprogrammed.
Enter command [9 6 0 #] to exit from installer's programming mode.
The STAY and the AWAY indicators are extinguished on the keypad to indicate that the
system is disarmed.
Remove the programming key from the control panel.
Enter [9 9 9 #] under installer's programming mode. The keypad will display the first
number.
Press [*] to display the next number.
Disconnect the AC MAINS supply and the backup battery from the control panel.
Short the default pads. The default pads is located on the right top of the PCB next to the
PROGRAMMING KEY socket.
Reconnect the power supply to the control panel.
If the LED on the control panel PCB fast flash, release the default pads at once.
The control panel is successfully defaulted to the factory settings.
If the LED on control panel PCB do not fast flash, the factory default is unsuccessful.
Installation Manual
System Functions | en
47
F.01U.241.127 | V4 | 2011.12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 2000 en

Table of Contents