Invalid parameter.
[Explanation] There is an error in the specified argument or operand.
[Remedy] Confirm the specified argument or operand and execute the command
once again.
Permission denied.
[Explanation] Do not have privilege.
[Remedy] Confirm the user privilege and the command privilege. In the case of
high-end servers, please also confirm whether command is executed by XSCF on
standby side.
An internal error has occurred. Please contact your system
administrator.
[Explanation] DR failed. There is a possibility that DR failed because of an
internal error in XSCF.
[Remedy] Find out the cause of the DR failure referring monitoring message and
error log. Please also confirm the XCP version.
A.2.5

setupfru

SB#XX is currently in use.
[Explanation] Because the system board of the PSB is running on the domain or is
assigned, PSB configuration cannot be changed.
[Remedy] Please confirm whether the system board of the PSB is assigned to the
domain or not, and release the system board if it is in the assigned status.
SB#XX is not installed.
[Explanation] Because PSB is not installed, it could not be set.
[Remedy] Please execute it again after confirming installation of the hardware.
Operation has completed. However, a configuration error was
detected.
[Explanation] Although configuration of PSB is changed, configuration error is
occurring on the system board created. Confirm the CPU module and DIMM slot
on the specified PSB and status of Memory Mirror Mode.
[Remedy] Confirm the CPU module and DIMM slot on the PSB board and status
of Memory Mirror Mode.