Fujitsu Siemens Computers SPARC Enterprise M5000 User Manual page 105

Fujitsu siemens servers dynamic reconfiguration (dr) user's guide
Table of Contents

Advertisement

8. Check the status of the domain.
Execute the showdcl(8) command to display domain information, and then
check the operation status of the domain. Based on the operation status of the
domain, determine whether to perform the DR operation or reboot the domains.
XSCF> showdcl -d 0
DID
LSB
XSB
00
00
00-0
01
01-0
9. Add the new system board to the domain.
Execute the addboard(8) command to add the system board to the move-
destination domain.
XSCF> addboard -c configure -d 0 01-0
10. Check the status of the domain and added system board.
When the addboard(8) command ends normally, execute the showdcl(8)
command to check the operation status of the domain, and then execute the
showboards(8) command to check the status of the added system board.
If the addboard(8) command completes abnormally or leaves the board in an
unwanted status, refer to output messages to identify the problem, then correct
it.
XSCF> showdcl -d 0
DID
LSB
XSB
00
00
00-0
01
01-0
XSCF> showboards 01-0
XSB
DID(LSB)
-----------------------------------------------------------------
01-0
00(01)
Status
Running
Status
Running
Assignment
Pwr
Conn
Assigned
y
y
Conf
Test
Fault
y
Passed
Normal
Chapter 4 Practical Examples of DR