8 1 3
Description
Selection
Default
Programming
Conditions
4-138
System Programming
4 9 0
Resource Programming
Floating Number Assignment
Assigns the floating numbers for External Pager, DISA message,
and extension groups. These numbers can be used the same way
extension numbers are used for station access.
Floating station: Pager / DISA / E-Group 1 through 8
l
Floating number: 2 through 4 digits
l
Pager=196; DISA=198; E-Group 1=191;
E-Group 2= 192; E-Group 3= 193; E-Group 4= 194;
E-Group 5=291; E-Group 6=292; E-Group 7=293;
E-Group 8=294
1.
Enter 813.
Display: 813 FLOATING #
2.
Press NEXT to program Pager 1.
Display example: Pager1
To program another floating station, keep pressing NEXT or PREV
until the desired floating station is displayed.
3.
Enter a floating number.
To change the current entry, press CLEAR and enter the new floating
number.
4.
Press STORE.
To program another floating station, keep pressing NEXT or
PREV until the desired floating station is displayed.
6
. Repeat steps 3 through 5.
Press END.
A floating number is composed of two to four numerical digits, 0
l
The first one or two digits of the floating numbers are subject to
l
program [lOO] "Flexible Numbering, (01) through (16) 1st through 16th
hundred extension blocks".