Using the ARM Command Line Utilities for Windows NT
Downloading Firmware
Copying Firmware From the Primary Controller to the Secondary Controller
For proper disk array operation, the disk array controllers must have matching firmware. If the firmware
revisions do not match, this procedure can be used to synchronize them. Firmware can also be copied from
the primary to the secondary controller using the disk array control panel.
CAUTION! The firmware code is copied from the primary controller to the secondary
controller, so before performing this task make sure the controller that has the desirable
code is designated the primary controller. See
instructions on changing the state of the controller.
To copy the firmware code from the primary controller to the secondary controller
1.
Gather the following information:
The ID of the disk array. The disk array ID can be displayed using the arraydsp -i command.
2.
From a command prompt type in the following command:
download -M <array-id>