Parameter
Array SCSI
configuration:
Controller X SCSI
Address
Controller Y SCSI
Address
Write Cache
ENABLED Indicates whether the disk array should cache write data.
Read Cache
DISABLED Indicates whether the disk array should cache read data.
SCSI Parity Checking ENABLED Indicates whether the disk array should check SCSI bus
SDTR
ENABLED Indicates whether the disk array should initiate SDTR
WDTR
ENABLED Indicates whether the disk array should initiate WDTR
Terminator Power
ENABLED Indicates whether the disk array should provide power for
Unit Attention
ENABLED Indicates whether the disk array should signal a Unit
Using the ARM Command Line Utilities for Windows NT
Viewing the Disk Array General Configuration Settings
Default
Setting
N/A
N/A
Indicates the SCSI bus address to be used by controller
X. Changes in this field will take affect only after controller
X is reset.
Indicates the SCSI bus address to be used by controller
Y. Changes in this field will take affect only after controller
Y is reset.
Generally, write cache is used even though a host system
automatically disables this field.
Note: This field does not represent what is actually
happening. The disk array uses read cache algorithms.
This field is put in place to facilitate some third party
operating systems.
parity. Disabled means that bus parity checking is
disabled. Enabled indicates that bus parity checking is
enabled.
(Synchronous Data Transfer Request). Disabled,
indicates the disk array will not initiate SDTR. Enabled
indicates the disk array will initiate SDTR.
(Wide Data Transfer Request). Disabled, indicates the
disk array will not initiate WDTR. Enabled indicates the
disk array will initiate WDTR.
the SCSI bus terminators. Disabled, indicates the disk
array will not provide termination power. Enabled
indicates the disk array will provide termination power.
Attention condition immediately following power-on or
reset. Disabled, indicates the disk array will not signal unit
attention. Enabled indicates the disk array will signal unit
attention.