HP Surestore Disk Array 12h - And FC60 System Administrator Manual page 41

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Table 5. arraymgr Disk Array Configuration Settings
Setting
Default
Active
On
Spare
Auto
On
Rebuild
Auto
On
Include
Rebuild
High
Priority
To change Active Spare, Auto Rebuild, or Auto Include settings, type:
arraymgr { -h | -a | -i } { on|off } <array-id>
To change Rebuild Priority setting, type:
arraymgr -p { high|low } <array-id>
Using the ARM Command Line Utilities for HP-UX
Changing Disk Array Configuration Settings
Command
Comments and Considerations
Option
-h
Active Hot Spare provides optimum
protection against disk failure. Disabling
Active Hot Spare will make additional
capacity available to the host, but at the
expense of maintaining full data
redundancy.
-a
Auto Rebuild provides optimum protection
against disk failure by rebuilding a failed
disk as quickly as possible. Disabling Auto
Rebuild gives you more control over the
rebuild process, but it can leave the disk
array vulnerable to a second disk failure
until a Rebuild is performed manually.
-i
Auto Include simplifies the task of adding
a new disk to your array. Disabling it will
require you manually to include each disk
you install in the array.
-p
Rebuild priority determines how quickly a
Rebuild operation will complete.
41