HP Surestore Disk Array 12h - And FC60 System Administrator Manual page 156

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Using the ARM Command Line Utilities for MPE
Viewing the Disk Array General Configuration Settings
Parameter
Capacity Depletion
Threshold
Write Working Set
Interval
Language
Log Full Warning
Volume Set
Partitioning
Format Pattern Fill
Disk array Type ID
LUN Creation Limit
Maximum LUN
Creation Limit
156
Default
Setting
0%
Indicates the amount of space below which the disk array
should signal a Capacity Depletion warning. For example,
if this field is set to 99% then when the disk array reaches
99% capacity, a Capacity Depletion warning will be
indicated. 0% means that Capacity Depletion warnings
will not be issued.
8640
Indicates the period (in ten second intervals) over which
seconds
write performance measurements should be gathered.
For example, 8640 X 10 = 86400 seconds = 24 hours.
ENGLISH Indicates the language used when displaying information
on the front panel.
DISABLED Indicates whether the disk array should assert a warning
when some portion of the controller log is full. When
enabled, the disk array will assert a Log Full Warning
when one of the disk array log pages fills, or a log
parameter reaches its maximum value. When disabled,
no Log Full Warning will be indicated.
DISABLED Indicates whether the disk array should boot when half or
more of the previously available drives are unavailable
(i.e., there is no drive quorum). Enabled indicates that
volume set partitioning should be allowed. Disabled, the
system will remain in the No Quorum state when the
required quorum is not available.
DISABLED Indicates whether the disk array will fill in incomplete
RAID blocks with a format pattern when performing new
writes. Some operating systems (not HP-UX, MPE, or
NT) expect that SCSI format commands completely
reinitialize data to a non-random pattern. When using the
array with one of those operating systems, pattern filling
should be enabled.
12
Uniquely identifies the disk array hardware configuration.
This field can be used to find the number of drives and
SCSI channels supported within the disk array.
8
Controls the range of LUNs that may be created.
8
Specifies the maximum supported value for the LUN
Creation Limit.
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents