HP Surestore Disk Array 12h - And FC60 System Administrator Manual page 63

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

The command options for arrayrecover are listed in
Option
-c
Used with other options, this will cause continuous polling during the
recovery. The recovery is monitored and the current progress is
displayed at regular intervals.
-l
Displays the array controller logs on standard output.
-lc
Displays the array controller logs on standard output, and then clears
the logs.
-p
Begin the recovery in non-interactive mode. If there are multiple volume
sets on the disk array, a list of the volume set numbers will be
displayed. If there is only one volume set on the disk array, the recovery
will be done on it. This option provides a mechanism to pass volume set
information to a script designed to perform a recovery.
-s
Returns the recoverability status of the disk array, as well as the status
of a recovery in progress. The status indicates if recovery is needed,
and what percentage of the entire recovery has been completed. When
used with the -c option, status will be returned at regular intervals
allowing continuous monitoring of the recovery progress.
-v volume_set_ID
Starts a recovery on the volume set indicated by volume-set-id. This
option is intended for use only in environments where there are multiple
volume sets on the disk array.
Using the ARM Command Line Utilities for HP-UX
Table 8. arrayrecover Command Options
Table
8.
Description
Recovering Data Maps
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents