Downloading Firmware - HP Surestore Disk Array 12h - And FC60 System Administrator Manual

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Downloading Firmware

The download command copies new firmware code to the controller(s) or individual disk mechanisms in
the disk array. Firmware also can be copied from a primary array controller to a secondary controller.
The ARMServer and arraymond processes continue to run while the download is in progress. However,
these processes may not be able to access the array during the download because the download operation
shuts down the disk array. This may cause warning messages such as the following to be displayed:
access error:
file name> at <machine name>
These warning messages can be ignored.
CAUTION! The firmware code is copied from the primary controller to the secondary
controller, so before performing this task make sure the controller that has the desirable
code is designated the primary controller. See
instructions on changing the state of the controller.
To download firmware to a disk, type:
download -D slot codefilename <array-id>
slot identifies the cabinet shelf containing the disk drive
codefilename identifies the file containing the firmware code
To download firmware to the disk array controllers, type:
download -C codefilename <array-id>
codefilename identifies the file containing the firmware code
To download firmware from the primary controller to the secondary controller, type:
download -M <array-id>
Using the ARM Command Line Utilities for HP-UX
Unable to get status from disk array on <raw disk
"Switching Primary
Downloading Firmware
Controllers" for
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents