WRTMT

The WRTMT command allows the user to perform a destructive write/read and verify test on the specified
target.
Synopsis
WRTMT
Output
ARDIAG> wrtmt
You must set the range variable before performing this task!
SOFTWARE ERROR(S) DETECTED BY ARDIAG
ARDIAG> range 0,1000/1200,45000
The selected disk has blocks from 0 to 4165271
RANGE: 0,1000/1200,45000
ARDIAG> wrtmt
***********************************************************************
*
***********************************************************************
* This test cannot continue without a loss of redundancy on the AutoRAID
* Array being tested!
* will result in DATA LOSS.
* result in direct data loss, it may take several hours before redundancy
* is restored and a disk failure can be tolerated without data loss.
***********************************************************************
Do you want to continue (y/[n])? y
The following data pattern options are available:
1 - Random pattern (0x00 to 0xFF)
2 - User defined
3 - Abort the test
Choose [1]: 2
Enter the pattern in hex format (0 to FF) [A5]: dd
The write data pattern will be 0xDD
Testing block 0.
percent
complete
100%
Test complete.
Using the ARDIAG Offline Diagnostic on MPE
W A R N I N G !
Failure of a disk before redundancy is restored
Although continuation of this test will NOT
Operational Command Descriptions
*