Using the ARDIAG Offline Diagnostic on HP-UX
Operational Command Descriptions
REQSENSE
The REQSENSE command allows the user to view SCSI Sense data from the specified target.
Synopsis
REQSENSE
Output
ARDIAG> REQSENSE
Performing Request Sense at TestLevel Indx 0
**********************************************************************
Error Code: 112 (0x70)
File mark bit is OFF
The Incorrect Length Indicator is OFF
Sense Key: NO SENSE (0x0)
The information field is NOT SCSI-2 compliant
Information field bytes: 0x0
Information as an int = 0 (0x0)
Command Specific Information field bytes: 0x0
Command Specific Info as an int = 0 (0x0)
Additional sense code = 0 (0x0) and qualifier = 0 (0x0)
Translates to: No additional sense information
Field replaceable unit code = 0 (0x0)
Sense Key Specific field is NOT valid
Sense key specific field = 0x0
Module Identifier is 0 (0x0)
Error Number is 0 (0x0)
94
|
Segment Number = 0 (0x0)
|
End of medium bit is 1349672
0x0
0x0
0x0
0x0
0x0
0x0
0x0
0x0
Need help?
Do you have a question about the Surestore Disk Array 12h - And FC60 and is the answer not in the manual?