Inquiry - HP Surestore Disk Array 12h - And FC60 System Administrator Manual

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

INQUIRY

The INQUIRY command allows the user to view SCSI Inquiry data from the specified target.
Synopsis
INQUIRY
Output
ARDIAG> INQUIRY
Performing Inquiry at TestLevel Indx 0
************************************************************
Peripheral Qualifier: Requested LUN is supported
Peripheral Device Type: Direct-access device
Medium is NOT removable
Device-type Modifier = 0(0x0)
ISO Version = 0
Device complies to present SCSI-2
Device does NOT support TERMINATE I/O PROCESS message
INQUIRY data format is as specified in SCSI-2
Other supported features:
16-bit wide data transfer, Synchronous data transfer, Tagged Command
Queuing
This device responds to a RESET condition with a SOFT RESET alternative
Vendor Identification: HP
Product Identification: C3586A
Product Revision Level: ZPRF
Requested Lun is Supported
Product Serial Number is ffffffffffffffffffffffffffffffff
Controller Pair Serial Number is
ffffffffffffffffffffffffffffffffffffffffffff
Backplane Serial Number is 007870ca0000
Requested Lun is Supported
Manufacturing Product Code is ManProdCod
Firmware Revision is 5D03159518
Number of Supported Logical Units = 32
Lun
Capacity (Logical Blocks)
===
=========================
0
2097152
1
4194304
2
6291456
Using the ARDIAG Offline Diagnostic on MPE
|
ECMA Version = 0 |
Operational Command Descriptions
ANSI Version = 2
179

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents