HP Surestore Disk Array 12h - And FC60 System Administrator Manual page 182

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Using the ARDIAG Offline Diagnostic on MPE
Operational Command Descriptions
Example 2: Internal disk drive
ARDIAG> testlevel 4
TESTLEVEL = 4
ARDIAG> readlog
Contents of drive log at TestLevel Indx 4
**********************************************************************
Vendor ID =
Product ID = 1.050 GB 3rd ###
Page Code 0
====================================================
Page Code 2 Error Counter Page (Write) Page [Write Errors]
Page Code 3 Error Counter Page (Read) Page [Read Errors]
Page Code 5 Error Counter Page (Verify) Page [Verify Errors]
Page Code 6 Non-Medium Error Page [Non-Medium]
Page Code 37 Vendor Unique or Non SCSI-2 Standard [Vendor Unique]
Page Code 3e Vendor Unique or Non SCSI-2 Standard [Vendor Unique]
Page Code 2
=======================================================
Errors Corrected With Possible Delays
Total Errors Corrected By Applying Retries
Total Errors Corrected
Total Times Correction Algorithm Processed
Total Bytes Processed
Total Uncorrected Errors
182
HP
Supported Log Sense Pages
Write Errors
=
0
=
0
=
0
=
0
=
(0x00000000200d6200)
=
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents