Device Adapter Configuration; Scsi Target Configuration - HP Surestore Disk Array 12h - And FC60 System Administrator Manual

System administrator's guide for hp-ux, mpe, and windows nt
Hide thumbs Also See for Surestore Disk Array 12h - And FC60:
Table of Contents

Advertisement

Device Adapter Configuration:

Configure the HP-PB Fast/Wide SCSI adapter using the SYSGEN ID of HP28696:
io> ap 10/16/4
id = hp28696a
io> lp 10/16/4
PATH:
10/16/4
ID:
HP28696A
PMGR:
FWSCSI_DAM
LMGR:

SCSI Target Configuration:

The next item to configure is the SCSI Target ID (TID). Since the AutoRAID is a multi-lun device, the TID
will be the same for each LDEV connected to any single AutoRAID. The SCSI Target will represent the
path to the controller that the SCSI cable is connected to.
NOTE: The setting of the initial SCSI TARGET(TID) and the SCSI LUN values on the AutoRAID
can be set by the front panel control. See User's and Service Manual for information on how to
use the front panel.
The SCSI Target ID of the controller is represented within SYSGEN using the ID of PSEUDO.
io> ap 10/16/4.1 id=pseudo
io> lp 10/16/4/1
PATH:
10/16/4/1
ID:
PSEUDO
PMGR:
TRANSPARENT_MGR
LMGR:
Managing the HP SureStore E Disk Array 12H on MPE
Configuring AutoRAID SCSI LUNs for MPE/iX
LDEV:
TYPE: DA
PMGRPRI:
6
MAXIOS:
0
LDEV:
TYPE: DA
PMGRPRI:
6
MAXIOS:
0
123

Advertisement

Table of Contents
loading

This manual is also suitable for:

Surestore e disk array 12h

Table of Contents