Using the ARDIAG Offline Diagnostic on MPE
Operational Command Descriptions
Output
Example 1: Controller
ARDIAG> testlevel 0
TESTLEVEL = 0
ARDIAG> download
************************************************************
*
************************************************************
The following options are available for DOWNLOAD to the array controller:
1 - Download a firmware image file to the primary controller with an
automatic update of same firmware to the secondary controller.
2 - Update the secondary controller with the same firmware as the
primary controller.
Choose [1]: 2
The primary controller is at XXXX
Do you want to do the update (y/[n])? y
Please be patient.
minutes.
WARNING!
IF YOU INTERRUPT THIS PROCESS, THE DEVICE COULD BE RENDERED INOPERATIVE!!
Shutting down the array...
Mirroring the microcode image...
Please wait while the array performs a reset...
************************************************************
*
Firmware Download Successful
************************************************************
ARDIAG>
174
Array Controller DOWNLOAD
The firmware download process may take several
*
*

Advertisement