Raidvchkdsp; Syntax; Options And Parameters - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

raidvchkset -g oralog -vt redo8
Sets volumes in oradat group as data file that Oracle block size is 8 KB:
raidvchkset -g oradat -vt data8 -vs 16
Sets volumes in oradat group as data file that Oracle block size is 16 KB:
raidvchkset -g oradat -vt data8 -vs 32
Releases all checking to volumes in oralog group:
raidvchkset -g oralog -vt
Sets Oracle10g volumes for oralog group as redolog file:
raidvchkset -g oralog -vt rd10g
Sets Oracle10g volumes for oradat group as data file with block size of 8 KB:
raidvchkset -g oradat -vt rd10g -vs 16
Disables writing to volumes in oralog group:
raidvchkset -g oralog -vg wtd
Disables writing and sets retention time to volumes in oralog group:
raidvchkset -g oralog -vg wtd 365
Releases all guarding to volumes in oralog group:
raidvchkset -g oralog -vg

raidvchkdsp

The raidvchkdsp command displays the parameters for validation checking of the specified volumes.
Unit of checking for the validation is based on the group of RAID Manager configuration definition
file.

Syntax

raidvchkdsp { -h | -q | -z | -I[H][M][instance#] or I[TC][SI][instance#]
| -g <group> | -d <pair Vol>
| -d[g] <seq#> <LDEV#> [MU#] | -f[xde] | -v <op> | -c }

Options and parameters

Option
-h
-q
-z or -zx
-I[H][M]
[instance#]
or
-I[TC][SI]
[instance#]
-g <group>
-d <pair Vol>
80
Replication commands
Description
Displays Help/Usage and version information.
Terminates the interactive mode and exits the command.
Makes the raidvchkdsp command enter the interactive mode. The -zx option guards performing of
the HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode
terminates.
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy],
and used when specifying the RAID Manager instance number.
Specifies a group name written in the configuration definition file.
Specifies paired logical volume name defined in the configuration definition file. When this option
is specified, the command is executed for the specified paired logical volume.
| -d[g] <raw_device> [MU#]

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents