7 Automatic recognition function of LUN
12 Undisplay function of ghost LUN
13 SIM report at link failure
14 HP TruCluster with Continuous Access Synchronous function
15 HACMP
22 Veritas Cluster Server
23 REC command support
33 Set/Report Device Identifier enable
40 V-Vol expansion
41 Prioritized device recognition command
42 Prevent "OHUB PCI retry"
43 Queue Full Response
54 Support Option for the EXTENDED COPY command
raidcom add path
Adds and changes an external path to an external volume. Only one path is operated in one
operation.
The order of priority for the oath is allocated in accordance with the order of adding paths.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.
Syntax
raidcom add path -path_grp <path group#> -port <port> -external_wwn <wwn strings>
Options and parameters
Option
-path_grp <path
group#>
-port <port>
-external_wwn
< wwn strings>
Examples
Adding a path of external port CL1-A, external storage system port 50060e80,05fa0f36 to an
external volume path group number: 1.
raidcom add path -path_grp 1 -port CL1-A -external_wwn 50060e80,05fa0f36
raidcom check_ext_storage path
Restores an external path to external VOLs. Only one path is operated in one operation.
166 Configuration setting commands
Description
Specifies an external VOL path group number (0-63231).
Specifies the number of the port whose attribute is External.
For example:
CL1-A
Specifies a WWN value (hexadecimal value) of the external storage system in 8 bytes. The
value can be split in units of 4 bytes by "," (commas).
For example:
21000e08b0256f8
21000e0,8b0256f8
Need help?
Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?