Raidar; Syntax - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Example of the -find option for raidscan
# ls /dev/rdsk/* | raidscan -find
DEVICE_FILE
/dev/rdsk/c0t0d4
/dev/rdsk/c0t0d1
/dev/rdsk/c1t0d1
Output of the raidscan command:
Port#, ALPA/C, TID#, LU#: Port ID, arbitrated loop physical address, TID, LUN.
For Business Copy, raidscan displays MU# for each LUN (e.g., LUN 7-0, 7- 1 , 7-2).
Num(LDEV#...): Number of LDEVs and LDEV ID for the LUSE volume.
P/S: Volume attribute.
Status: Status of the paired volume.
Fence: Fence level (Continuous Access Synchronous only).
P-Seq#: Serial # of the storage system which contains the partner volume of the pair.
P-LDEV#: LDEV number of the partner volume of the pair.
Vol.Type: Logical unit (LU) type (For example, OPEN-V, OPEN-9).
Group: Group name (dev_group) as described in the configuration definition file.
UID: Displays the unit ID for multiple storage system configuration. If UID appears as '-', the
command device for HORCM_CMD is not found.
S/F: Displays whether a port is SCSI or fibre.
PORT: Displays the RAID storage system port number.
TARG: Displays the target ID (which was converted by the fibre conversion table).
LUN: Displays the LUN (which was converted by the fibre conversion table).
SERIAL: Displays the production (serial#) number of the RAID storage system.
LDEV: Displays the LDEV# within the RAID storage system.
PRODUCT_ID: Displays product-id field in the STD inquiry page.

raidar

The raidar command displays configuration, status, and I/O activity information for the specified
port/TID(s)/device(s) at the specified time interval. The configuration information is acquired directly
from the storage system (not from the configuration definition file).
The I/O activity of a Continuous Access Synchronous S-VOL in the COPY or PAIR state includes
Continuous Access Synchronous remote I/Os (update copy operations) in addition to host-requested
I/Os. The I/O activity of a Business Copy S-VOL in the COPY or PAIR state includes only
host-requested I/Os (Business Copy update copy operations are excluded). The I/O activity of a
P-VOL or simplex volume includes only host-requested I/Os. If state changed into SMPL in S-VOL
(COPY, PAIR) I/O actively, and then I/O activity of the between is reported in the SMPL state.

Syntax

raidar { -h | -q | -z | -I[H][M][instance#] or I[TC][SI][instance#]
| -p
| -s [interval] [count] }
UID
S/F PORT
0
S
CL1-M
0
S
CL1-M
-
-
CL1-M
<port>
<targ>
<lun> | -pd[g] <raw_device
TARG
LUN
SERIAL
0
4
31168
0
1
31168
-
-
31170
LDEV
PRODUCT_ID
216
OPEN-3-CVS-CM
117
OPEN-3-CVS
121
OPEN-3-CVS
raidar
73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents