Returned Values; Error Codes; Examples - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Option
-p <port> [hgrp]
-pd[g]
<raw_device>
-s <Seq#>
-t <target>
-l <lun>
-fx
-v [op]

Returned values

None

Error codes

None

Examples

Examples of the raidvchkscan command and its output follows.
Description
Specifies the port ID of the port to be scanned. Valid ports are CL1-A to CL1-R and CL2-A to CL2-R
(excluding CL1-I, CL1-O, CL2-I, CL2-O). In addition:
For XP24000/XP20000 Disk Array: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port For
XP12000 Disk Array: CL3-a to CL3-r, or CLG-a to CLG-r for the expanded port.
For XP10000 Disk Array: CL3-a to CL3-h, or CL8-a to CL8-h for the expanded port.
For XP1024/XP128 Disk Array: CL3-a to CL3-r, or CL4-a to CL4-r for the expanded port.
The port is not case sensitive (For example, CL1-A= cl1-a= CL1-a= cl1-A, CL3-a= CL3-A= cl3-a=
cl3-A). This option must be specified if "-find" or "-pd <raw_device>"option is not specified.
Specify [hgrp] to display only the LDEVs mapped to a host group on a port (XP1024/XP128 Disk
Array and later).
Specifies the raw device name. This option finds Seq# and port_name of the storage system to which
the specified device can be connected, and scans the port of the storage system which corresponds
with the unit ID that searches the unit ID from Seq#. This option must be specified if the "-find" option
is not specified. If this option is specified, the following -s <Seq#> option is invalid.
-pdg (XP1024/XP128 Disk Array and later): Shows a LUN on the host view by finding a host group.
Used to specify the Seq# (serial#) of the storage system when this option cannot specify the unit ID
which is contained for "-p <port>" option. This option scans the port specified by "-p <port>" option
of the storage system which corresponds with the unit ID that searches the unit ID from Seq#. If this
option is specified, then the unit ID which is contained in "-p <port>" option is invalid.
Specifies a target ID (0 to 15) of the specified port. If this option is not specified, the command
applies to all target IDs.
Specifies a LUN (0 to 7) of the specified target ID. If this option is not specified, the command applies
to all LUNs. If this option is specified, the TID must also be specified.
Displays the LDEV/STLBA/ENLBA number in hexadecimal notation.
Specifies the following operation that displays each parameter for validation checking:
cflag: Displays all flags for checking regarding data block validation for target vols.
offset: Displays the range setting for data block size of Oracle I/O and a region on a target volume
for validation checking.
errcnt: Displays the statistical information counted as an error for each checking on the target volumes.
Each statistical information counted as an error is cleared when the individual flag for validation
checking is disabled.
gflag: Displays the parameter for guarding on the specified target volumes.
pool: This option displays the pool capacity and the usable capacity for the pool ID to which the
LDEV belongs. This is needed to help the decision whether the restore operation is possible or not,
because the pool capacity is consumed by the restore operation of the Snapshot.
aou[b]: Displays the LUN capacity and usage rate for only Thin Provisioning volume mapped to the
specified port, and displays the ID of the pool to which LDEV belongs.
aoub: Displays the LUN capacity in units of block/512 bytes.