Syntax; Options And Parameters; Examples - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

Syntax

Specify more than one option when specifying the data overflow watching time of journal data
area, path blocked watch or the timer type, specify more than one option.
raidcom modify journal -journal_id <journal ID#> {[-data_overflow_watch<time>]
[-cache_mode <y/n>][-timer_type <type>]}
When specifying the path blocked watch or the Mirror ID.
raidcom modify journal -journal_id <journal ID#> -path_blocked_watch <time>
[-mirror_id <mun#>]
When specifying the MP Blade ID.
raidcom modify journal -journal_id <journal ID#>

Options and parameters

Option
-journal_id <journal ID#>
-data_overflow_watch<time(sec)>
-path_blocked_watch<time(min)>
-cache_mode <y/n>
-timer_type <timer type>
-mp_blade_id <mp#>
-mirror_id <mun#>

Examples

Changing the setting of a journal: 6. Changing the data overflow watch time to 15 seconds.
# raidcom modify journal -journal_id 6 -data_overflow_watch 15
Changing the setting of a journal: 6. Changing the data overflow watch time to 15 seconds.
Changing the timer type to the system clock of the mainframe host.
# raidcom modify journal -journal_id 6 -data_overflow_watch 15 -timer_type system
150 Configuration setting commands
Description
Specifies a journal number (0-255).
The data overflow watch timer (0-600) (seconds).
Specifies the watch time for the journal data area being full.
The watch for the path blockage (1-60) (minutes).
Use Remote Web Console to set the value with more than 60 minutes.
If 0 is specified, the time of the watch for the path blockage does not
change, and the watch for the path blockage is invalid.
Specifies whether to use the cache mode.
y: Cache mode enabled (E)
n: Cache mode disabled (D)
Specifies a timer type among system, local or None. For details, see the
Cnt Ac-J manual for the Timer Type option.
For example:
-timer_type system
-timer_type system
Specifies an MP Blade ID (0-7).
Changing MP Blade ID should be executed during off-peak hours of I/O
loading. Do not change the MP blade ID during initial copying of
Continuous Access Journal (on-peak hours of I/O loading).
To change the MP Blade ID again for the same journal, wait for more than
30 minutes after changing the MP Blade ID.
For example:
-mp 2
Specifies a Mirror ID.
If the setting is omitted, "0" is used.
-mp_blade_id <mp#>

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents