Examples

Serial Number: Register P9500 of Serial number 64034 with CU free. Sets the port on MCU:
CL1-A and the port on RCU: CL1-B.
raidcom add rcu -cu_free 64034 R500 1 –mcu_port CL1-A –rcu_port CL1-B

raidcom delete rcu

Deletes the RCU.
This command is executed asynchronously with the command input. Check the completion of this
process on the raidcom get command_status command.

Syntax

raidcom delete rcu -cu_free <serial#> <id> <pid>

Options and parameters

Option
-cu_free <serial#><id><pid>
Examples
Deleting the P9500 for which the product number; 64034, the RAID type: P9500 and the path
group ID: 1 are set.
raidcom delete rcu -cu_free 64034 R700 1

raidcom get rcu

Displays MCU/RCU information.
Syntax
raidcom get rcu [-cu_free <serial#> <id> <pid>]
Options and parameters
Option
[-cu_free <serial#><id><pid>]
Examples
Displaying RCU information.
# raidcom get rcu
Serial# ID PID MCU RCU M/R T STS MP NP IM FZ RTO(s) RTT(ms)
178 Configuration setting commands
Description
-cu_free <serial#> <id> <pid>
This parameter is used to specify CU free that is specified by Serial#, id#, pid#.
< id > is used to set RAID Type, and it can be specified the following strings.
XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk
Array:R600, P9500:R700
< pid> is used to set the path group ID (0-255).
Description
-cu_free <serial#> <id> <pid>
This parameter is used to specify CU free that is specified by Serial#, id#, pid#.
< id > is used to set RAID Type, and it can be specified in the following strings.
XP12000 Disk Array/XP10000 Disk Array:R500, XP24000/XP20000 Disk
Array:R600, P9500:R700
<pid> is used to set the path group ID (0-255).