Returned values

The horctakeoff command sets the following returned values during exit, allowing you to check the
execution results.
Normal termination: 0
Abnormal termination: The horctakeoff command returns the following error codes as well as a
generic error.

Error codes

If the command failed, then the detailed status is logged in RAID Manager command log
($HORCC_LOG), even though the user script has no error handling.
Category
Volume status
Unrecoverable
Timer
Recoverable

Examples

Example 1
horctakeoff command on L1 local site
# horctakeoff -g G1 -gs G2
horctakeoff : 'pairsplit -g G1 -S -FHORC 2' is in progress
horctakeoff : 'pairsplit -g G1' is in progress
horctakeoff : 'pairsplit -g G2 -S' is in progress
horctakeoff : 'paircreate -g G1 -gs G2 -FHORC 2 -nocopy -f async -jp 0 -js 1' is in progress
horctakeoff : 'pairsplit -g G1 -FHORC 2' is in progress
horctakeoff : 'pairresync -g G1' is in progress
horctakeoff : 'pairresync -g G1 -FHORC 2' is in progress
horctakeoff : horctakeoff done
Example 2
horctakeoff command on L2 local site
100 Replication commands
Error code
Error message
EX_ENQVOL
Unmatched volume status within the group
EX_INCSTG
Inconsistent status in group
EX_EVOLCE
Pair Volume combination error
EX_VOLCRE
Local and Remote Volume currency error
EX_EWSTOT
Timeout waiting for specified status
Value
236
229
235
223
233