HP StorageWorks P9000 - Disk Arrays Reference Manual page 180

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

If CU free is specified for RCU, "-" is displayed.
-RTO (s)
This displays the timeout value for RIO (Remote IO) setting between MCU and RCU.
-RTT (ms)
This displays the round trip time value between MCU and RCU.
# raidcom get rcu -cu_free 64034 4 1
Serial# ID PID MCU RCU M/R T PNO MPORT RPORT STS_CD SSIDs
64034 R7 1 - - RCU F 1 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 2 CL1-A CL1-B NML_01 -
64034 R7 1 - - RCU F 3 CL1-A CL1-B NML_01 -
Description on each column in output example
-Serial#
Product serial number.
-ID
This displays the ID for identifying RAID type.
XP12000 Disk Array/XP10000 Disk Array :R5, XP24000/XP20000 Disk Array : R6, P9500 : R7
PID
This displays a path group ID.
If CU is specified for RCU, "-" is displayed.
-MCU
This displays the CU number (hexadecimal) as MCU.
If CU free is specified for RCU, "-" is displayed.
-RCU
This displays the CU number (hexadecimal) as RCU.
If CU free is specified for RCU, "-" is displayed.
-M/R
This displays the CU type as MCU/RCU.
-T
This displays the type of physical path.
F: FIBRE, E:ESCON,
-PNO
This displays the path number.
-MPORT
This displays the MCU port number.
-RPORT
This displays the RCU port number.
-STS_CD
This displays the following status of the path.
- NML_01: this means the status of "Normal" in path.
- ERR_02: this means the status of "Initialization Failed" in path.
- ERR_03: this means the status of "Communication timeout" in path.
- ERR_04: this means the status of "Logical Blockade" in path.
180 Configuration setting commands

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF