Examples - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

It shows the progress situation when formatting or shredding. When the status is other than formatting
or shredding, 100 is displayed. If the process ends abnormally, "BSY" is displayed on the "STS".
MP#
It shows the MP Blade ID.

Examples

Displaying front-end information of the LDEV number 577.
# raidcom get ldev -ldev_id 577 -key frnt Serial# LDEV# SL CL VOL_TYPE VOL_Cap(BLK) PID ATTRIBUTE
Ports PORT_No:LU#:GRPNAME
CVS 2 CL2-E-0:1:Linux_X86 CL2-E-1:1:Solaris
Displaying back-end (parity group) information of the LDEV number 577.
# raidcom get ldev -ldev_id 577 -key rgrpSerial# LDEV# SL CL PID ATTRIBUTE R_LVL RAID_TYPE DRV_TYPE DRV_Cap
GRPs RAID_GRP
Displaying the information of the LDEV number 160 (external VOL).
# raidcom get ldev -ldev_id 160
Serial#
: 63502
LDEV : 160
SL : 0
CL : 0
VOL_TYPE : OPEN-V
VOL_Capacity(BLK) : 4385280
NUM_PORT : 0
PORTs :
F_POOLID : NONE
VOL_ATTR : ELUN
E_VendorID : HITACHI
E_ProductID : OPEN-V
E_VOLID : 484954414348492052353030463830453030364100000000000000000000000000000000
E_VOLID_C : HITACHI R500F80E006A................
NUM_E_PORT : 1
E_PORTs : CL2-G-0 0 50060e8004f80e34
LDEV_NAMING : Oracle_data_1
STS : NML
OPE_TYPE : QFMT
OPE_RATE : 70
MP# : 2
Description on each column in output example
E_VendorID
This displays the VENDOR information in the SCSI information of the external volume.
E_ProductID
This displays the PRODUCT information in the SCSI information of the external volume.
E_VOLID
This displays the device identification information in the SCSI information of the external volume
(display in hexadecimal notation).
E_VOLID_C
This displays the PRODUCT information in the SCSI information of the external volume (ASCII
display).
NUM_E_PROTs
This displays the number of alternate paths.
E_PORTs
It enumerates the defined alternate paths.
Examples
If the LDEV number 160 is an external volume, its back-end (RAID Group) information is displayed.
Displaying the information of the LDEV number 640 (V-VOL of Thin Provisioning).
158 Configuration setting commands
63502 577 0 0 OPEN-V-CVS 2181120 -
63502 577 0 0 - CVS RAID1 2D+2D DKS2C-K072FC 141822798 1 02-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents