Examples; Raidscan; Syntax; Options And Parameters - HP StorageWorks P9000 - Disk Arrays Reference Manual

Hp storageworks p9000 raid manager reference guide (t1610-96030, january 2011)
Hide thumbs Also See for StorageWorks P9000 - Disk Arrays:
Table of Contents

Advertisement

status is logged in the RAID Manager command log ($HORCC_LOG), even if the user script has
no error handling.
Table 18 Error codes for horctakeover
Category
Volume status
Unrecoverable
Timer Recoverable

Examples

For examples of the hortakeover command, see Horctakeover command functions in the User and
Reference Guide.

raidscan

The raidscan command displays configuration and status information for the specified
port/TID(s)/device(s). The information is acquired directly from the storage system (not the
configuration definition file).

Syntax

raidscan { -h | -q | -z | -I[H][M][instance#] or I[TC][SI][instance#]
| -p <port> [hgrp]|-pd[g] <raw_device> | -s <Seq#> | -t <targ>
| -l <lun> | [ -f[xfgde] ] | -CLI | -find[g] [op] [MU#]
| -pi <strings> | -m <MU#> }

Options and parameters

Option
-h
-q
-z or -zx
-I[H][M]
[instance#]
or
-I[TC][SI]
[instance#]
66
Replication commands
Error code
Error message
EX_ENQVOL
Unmatched volume status
within the group
EX_INCSTG
Inconsistent status in group
EX_EVOLCE
Pair Volume combination
error
EX_VOLCUR
S-VOL currency error
EX_VOLCUE
Local Volume currency error
EX_VOLCRE
Local and Remote Volume
currency error
EX_EWSTOT
Timeout waiting for specified
status
Description
Displays Help/Usage and version information.
Terminates the interactive mode and exits the command.
Makes the raidscan command enter the interactive mode. The -zx option guards performing of the
HORCM in the interactive mode. When this option detects a HORCM shutdown, interactive mode
terminates.
OpenVMS cannot use the -zx option.
Specifies the command as [HORC]/[HOMRCF] or [Continuous Access Synchronous]/[Business Copy],
and used when specifying the RAID Manager instance number.
Recommended action
Confirm status using pairdisplay
command. Make sure all volumes in the
group have the same fence level and
volume attributes.
Confirm pair status using pairdisplay.
Confirm pair status using pairdisplay,
and change combination of volumes.
Check volume list to see if an operation
was directed to the wrong S-VOL.
Confirm pair status of the local volume.
Confirm pair status of remote and local
volumes using pairdisplay command.
Increase timeout value using -t option.
Value
236
229
235
225
224
223
233

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents