EPSON ColorPage EPL-C8200
3.2.8.11 REGI. SENSOR Removal (PL5.2.28)
1. Remove the MSI TRAY ASSEMBLY. (See Section 3.2.7.1.)
2. Remove the MSI ASSEMBLY. (See Section 3.2.7.2.)
3. Remove the MAIN P/H ASSEMBLY. (See Section 3.2.8.1.)
NOTE: In the following step, hold the REGI. CHUTE ASSEMBLY to
keep it closed while turning over the MAIN P/H ASSEMBLY.
4. Disconnect the connector (P/J93) for REGI. SENSOR from the back
of the MAIN P/H ASSEMBLY.
NOTE: In the following step, be careful not to break the hooks in the
P/H FRAME ASSEMBLY.
5. Release the hooks on the P/H FRAME ASSEMBLY securing the
REGI. SENSOR and lift the sensor up vertically to remove.
Chapter 3
Disassembly and Assembly/Adjustment
Figure 3-55. REGI. SENSOR Removal
When installing the REGI. SENSOR, make sure the
sensor is securely hooked to the P/H FRAME
ASSEMBLY.
Revision A
3-48