EPSON ColorPage EPL-C8200
3.2.12.4 FUSER UPPER ASSEMBLY Removal (PL9.2.23)
1. Remove the EXIT TRAY ASSEMBLY. (See Section 3.2.13.1.)
2. Remove the OIL ROLL ASSEMBLY. (See Section 3.2.12.1.)
3. Remove the FUSER ASSEMBLY. (See Section 3.2.12.2.)
4. Remove the MAIN FUSER ASSEMBLY. (See Section 3.2.12.3.)
NOTE: In the following step, be careful not to damage the HEAT
ROLL surface with a driver when remove the TEMP.
SENSOR ASSEMBLY.
5. Remove the screw (silver, tapped, 14mm) securing the TEMP.
SENSOR ASSEMBLY and release the harness from the hook on
the FUSER UPPER ASSEMBLY.
NOTE: In the following step, be careful not to drop the FUSER
FRONT COVER and the FUSER REAR COVER since they
will not be supported as the FUSSER UPPER ASSEMBLY is
removed.
6. Remove the following 4 screws securing the FUSER UPPER
ASSEMBLY.
-2 outer screws (gold, with a washer, 8mm) sealed with black tapes
-2 inner screws (silver, 6mm)
Chapter 3
Disassembly and Assembly/Adjustment
Figure 3-96. FUSER UPPER ASSEMBLY Removal
When installing the FUSER UPPER ASSEMBLY, fasten
the screws (Step 6) with the following parts:
Outer screws: H/R HEATER
Inner screws: HEATER WIRE
Revision A
3-79