CHAPTER 6 FIXING SYSTEM
8) Open the upper feeding unit
place it on a desk.
Caution:
Draw out the silicone oil in advance from the silicone oil pan to avoid spilling it
during work.

6. Removing the Fixing Heater

1) Slide out the fixing/feeding unit from the copier.
2) Remove the fixing/feeding front cover.
3) Open the fixing delivery assembly.
4) Remove the flywheel.
5) Remove the upper fixing cover, and remove the fixing cleaning belt; then, clean the
silicone oil pan, and remove the fixing upper unit.
6) Pull out the faston
7) Remove the mounting screw
.
6-22
COPYRIGHT © 1997 CANON INC.
slightly, and remove it in the upper left direction; then,
Figure 6-213
from the front of the hater (main heater, sub heater).
, and remove the front electrode support plate spring
CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)