CHAPTER 10 TROUBLESHOOTING
D. Control Display Mode (
Press the <</>> key to select the screen.
Item
FTMP
Indicates the surface temperature of the fixing roller.
(output of the main thermistor TH1)
RTMP
Indicates the machine internal temperature. (output of
the thermal sensor on the DC controller PCB)
RHUM
Indicates the machine internal humidity. (output of the
humidity sensor on the DC controller PCB)
LMP1
Indicates the ON voltage of the scanning lamp
(100/120V model)
LMP2
Indicates the ON voltage of the scanning lamp. (230V
model)
WIRE
Indicates a value other than '0' if the primary, pre-
transfer, or transfer/separation charging wire cleaner
stops at a point not its home position. Executing wiring
cleaning for the appropriate wire in user mode will
return the wire cleaner to its home position.
PLMT
Indicates '1' when the current value reaches the upper
limit or the lower limit during current control on the
primary charging assembly.
LLMT
Indicates '1' when the ON voltage of the scanning
lamp reaches '1' and '2' if it reaches the lower limit.
10-142