Removing The Process Unit - Canon NP6045 Service Manual

Table of Contents

Advertisement

6. Removing the Process Unit

1) Open the front door.
2) Remove the developing assembly. (See p. 4-55.)
3) Remove the hopper assembly. (See p. 4-60.)
4) Slide out the fixing feeding assembly, and place the drum protection sheet on the
registration roller assembly.
5) Disconnect the four connectors
6) Insert the drum rotating tool
drum in place so that it will not rotate in counterclockwise direction, insert a
screwdriver through the center hole
drum fixing screw.
Caution:
Do not remove the drum fixing screw before fixing the drum in place. If the drum is
allowed to rotate in counterclockwise direction, the cleaning blade will not come into
contact with the drum correctly, leading to cleaning faults.
Reference:
If you are releasing the hopper assembly but not removing it, be sure to open the
multifeeder door and the upper right door to allow for space for the front door.
COPYRIGHT © 1997 CANON INC.
, and remove the two mounting screws
Figure 7-410
into the slit
CANON NP6045 REV. 1 MAR. 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 7 EXTERNALS/AUXILIARY MECHANISMS
in the drum shaft. While keeping the
of the drum rotating tool; then, remove the
.
7-17