2.3 Transfer Roller 2 Replacement
<Criterion of Replacement>
The transfer roller 2 should be replaced at the same time as a new discharger unit
according to the periodical maintenance cycle set out in Table 6-4.
When time is due for replacement of the transfer roller 2, the following message
appears on the control panel. (The display is blinked.)
<Purpose of Replacement>
To prevent the transfer efficiency declining due to deterioration of the transfer roller
2.
<Necessary Tools and Replacement Materials>
1) Two or three pieces of cotton cloth for cleaning.
2) Transfer roller 2 (one unit)
<Work Procedures>
Sequence of Disassembling
1) After turning off the remote switch and power supply, unplug the power code
from the power outlet.
2) Open the transfer unit 2.
REPLACE 120K KIT
Transfer unit 2
Fig.6-23
VI-27