I-19
Mottle
Phenomenon
Variation of the scanning density is found in the image as shown in
Fig.8-2.
Main Causes
1) The transfer unit 2 is not fixed in place.
2) Assembly of the transfer roller 2 is inaccurate.
3) THV output of high voltage unit is not normal.
4) Failure of the toner cartridge.
5) Deformation of the print paper.
Countermeasures
1) Confirm that the transfer unit 2 is firmly locked in place.
2) Confirm that the transfer roller 2 is properly installed.
3) Replace the high voltage unit with a new one. (See
4) Replace the toner cartridge with a new one.
5) Replace the paper with new paper from a freshly opened ream.
I-20
Residual Image
Phenomenon
Image of the preceding page appears on every other page as shown in
of
Fig.8-2.
Main Causes
1) Cleaning failure due to lifting of the cleaning brush of the drum cleaner 2.
2) Contact failure of the drum cleaner 's bias pole.
3) Failure of high voltage unit.
Countermeasures
1) Check if the drum cleaner 2 is properly installed or not.
2) Replace the failed high voltage unit with a new one. (See
VII.)
print sample (19) of
Section 4.3.6 of Chapter
print sample (20)
Section 4.3.6 of Chapter
VII.)