Severity
CRITICAL
DIAG-LCMTO
Message
<timestamp>
CRITICAL DIAG-LCMTO, 1, <test name>, pass <number>,
Pt<port information> CMEM Timeout during a [read/write],
mem_ctl's MEM_RUNNING bit 0 Stuck High,
Err# <error code>
Probable Cause
A central memory timeout occurred: data transfer initiated did not complete within the timeout
period. This usually indicates an ASIC failure. This message is generated by the
centralmemorytest and cmemretentiontest commands. The error code value
is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-MEMNULL
Message
<timestamp>
CRITICAL DIAG-MEMNULL, 1, <test name>,
Failed to malloc memory,
Err# <error code>
Probable Cause
The ASIC failed to allocate memory. This usually indicates a motherboard failure. This
message is generated by the ramtest command. The error code value is for internal use
only.
Fabric OS 3.x Document Addendum
Diagnostic and system error messages reference guide
99