Fabric OS reference guide
Operands
None
Example
To set the SNMP MIB and trap capabilities of a switch:
Cylon51:admin> snmpmibcapset
The SNMP Mib/Trap Capability has been set to support
FE-MIB
SW-MIB
FA-MIB
SW-TRAP
FA-TRAP
FA-MIB (yes, y, no, n): [yes] n
SW-TRAP (yes, y, no, n): [yes]
SW-EXTTRAP (yes, y, no, n): [no] y
Committing configuration...done.
See Also
agtcfgdefault
agtcfgset
agtcfgshow
218
swFCPortScn
swEventTrap
swFabricWatchTrap
swTrackChangesTrap
connUnitStatusChange
connUnitEventTrap
connUnitSensorStatusChange
connUnitPortStatusChange
swFCPortScn (yes, y, no, n): [yes]
swEventTrap (yes, y, no, n): [yes] n
swFabricWatchTrap (yes, y, no, n): [yes]
swTrackChangesTrap (yes, y, no, n): [yes] n