Diagnostic and system error messages reference guide
DIAG-CMINOCAP
Message
<timestamp>
CRITICAL DIAG-CMINOCAP, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: RX Pt<fail port> Failed to
get CMI Capture Flag (bit31 is 0),
Err# <error code>
Probable Cause
The CMI recipient ASIC failed to get a CMI capture flag. This usually indicates an ASIC or
motherboard failure. This message is generated by the cmitest command. The error
code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMISA1
Message
<timestamp>
CRITICAL DIAG-CMISA1, 1, <test name>, pass <number>,
Pt<source port info>-Pt<destination port info>: TX Pt<fail port> CMI
Self-Test Start bit30 s-a-1,
Err# <error code>
Probable Cause
An attempt to send a CMI message from one ASIC to another failed. This usually indicates an
ASIC failure. This message is generated by the cmitest command. The error code
value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL