HP StorageWorks 2/16 - SAN Switch Manual page 84

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Diagnostic and system error messages reference guide
DIAG-CMBISRF
Message
<timestamp>
CRITICAL DIAG-CMBISRF, 1, <test name>, pass <number>,
Pt<port information> BISR,BIST Self-Test Failed,
RAMs fail bitmap: is 0x<actual value> sb 0x<expected value> er 0x<err
value>,
Err# <error code>
Probable Cause
The ASIC central memory SRAMs did not complete the BISR within the timeout period. This
usually indicates an ASIC failure. This message is generated by the centralmemorytest
command. The error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-CMBISRTO
Message
<timestamp>
CRITICAL DIAG-CMBISRTO, 1, <test name>, pass <number>,
Pt<port information> BISR,BIST Timed Out,
RAMs done bitmap: is 0x<actual value> sb 0x<expected value> er 0x<err
value>,
Err# <error code>
Probable Cause
The ASIC central memory SRAMs did not complete the BISR within the timeout period. This
usually indicates an ASIC failure. This message is generated by the centralmemorytest
command. The error code value is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
84
Fabric OS 3.x Document Addendum

Advertisement

Table of Contents
loading