HP StorageWorks 2/16 - SAN Switch Manual page 113

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

D-list conflict
Recommended Action
If the reconfiguration was unplanned, check for problems with the specified port. Some
troubleshooting tasks consist of:
Refer to the Fibre Channel Standard FC-SW3, Chapters 6 and 7, for more information on
fabric initialization.
Severity
INFO
MS-CT_REQUEST_FAIL
Message
<timestamp>
WARNING MS-CT_REQUEST_FAIL, 3, MS CT request failure for domain <domain>
(cmd=0xF004, code=0xFFFFFFFF)
Probable Cause
The management server (MS) received an invalid common transport (CT) response from
switch domain. MS expects either a CT accept IU or a reject IU; the management server
received neither response, which violates the Fibre Channel Generic Services (FS-GS)
specification.
Recommended Action
Check the integrity of the FC switch at the specified domain. It is not sending correct MS
information as defined by the FC-GS standard.
Severity
WARNING
Fabric OS 3.x Document Addendum
Verifying that the port was not disabled, using the portshow command
Verifying that the port is cabled correctly
Verifying that the SFP has not deteriorated
Diagnostic and system error messages reference guide
The principal switch received a domain list that contains
more domains than what the principal switch has already
assigned.