HP StorageWorks 2/16 - SAN Switch Manual page 106

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Diagnostic and system error messages reference guide
DIAG-REGERR_UNRST
Message
<timestamp>
CRITICAL DIAG-REGERR_UNRST, 1, <test name>,
Pt<port info> failed to unreset despite <number> retries,
lli_ctl is <actual value> sb 90000, port_config is <actual value> sb 0,
Err# <error code>
Probable Cause
The port failed to un-reset. This usually indicates an ASIC failure. This message is generated
by the portregtest or the sramretentiontest command. The error code value
is for internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-STATS (C3FRX)
Message
<timestamp>
CRITICAL DIAG-STATS (C3FRX), 1, <test name>, pass <number>,
Pt<port info> Cl3FrmRx Counter Wrong, is <actual value> sb <expected
value>,
Err# <error code>
Probable Cause
The port counter value did not match the number of frames actually transmitted. In this case,
Cl3FrmRx equals the number of Class 3 frames received. This can be caused by a faulty
cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or
ASIC. This message is generated by the portloopbacktest command. The error
code value is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
106
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Fabric OS 3.x Document Addendum

Advertisement

Table of Contents
loading

Table of Contents