HP StorageWorks 2/16 - SAN Switch Manual page 206

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Fabric OS reference guide
The second column displays Link Error Status Block counters:
Link_failure
Loss_of_sync
Loss_of_sig
Protocol_err
Invalid_word
Invalid_crc
Delim_err
Address_err
Lr_in
Lr_out
Ols_in
Ols_out
The third column displays the number of F_RJTs and F_BSYs generated. For L_Ports, the
third column also displays the number of LIPs received, the number of LIPs transmitted, and
the last LIP received.
Frjt
Fbsy
Operand
The following operand is required:
port_number
206
Number of times the port enters LF1 or LF2 state.
Number of times the port enters a loss of sync state.
Number of times the port enters a loss of signal state.
Number of occurrences of the link failure condition in
which either an LR or LRR primitive sequence was
received while in OL3 (wait for OLS) state.
Number of encoding/disparity errors inside of frames.
Number of CRC errors.
Number of SOF or EOF errors.
Number of IUs with a nonzero status received.
Number of link reset requests received.
Number of link reset requests sent out.
Number of OLS Primitives received.
Number of OLS Primitives sent out.
Number of fabric reject messages sent out.
Number of fabric busy messages sent out.
The port number to be displayed: 0 through 7 or 0 through 15.
Fabric OS 3.x Document Addendum

Advertisement

Table of Contents
loading

Table of Contents