HP StorageWorks 2/16 - SAN Switch Manual page 126

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Diagnostic and system error messages reference guide
SEC-SECVIOL_MSop
Message
<timestamp>
INFO SEC-SECVIOL_MSop, 4, Security violation: MS device <device wwn>
operates on non primary FCS switch.
Probable Cause
An MS operation security violation was reported. A management server device is operating on
a nonprimary FCS switch.
Recommended Action
Check the management server policy and verify that the connection is allowed. If the
connection is allowed but not specified, enable the connection in the MS policy.
If the MS policy does not allow the connection, this is a valid violation message and an
unauthorized entity is trying to access your fabric. Take appropriate action as defined by your
enterprise security policy.
Severity
INFO
SEC-SECVIOL_RSNMP
Message
<timestamp>
INFO SEC-SECVIOL_RSNMP, 4, Security violation: Unauthorized host with IP
address <IP address> tries to do SNMP read operation.
Probable Cause
An SNMP security violation was reported. The specified unauthorized host attempted to
perform a read SNMP operation (RSNMP).
Recommended Action
Check RSNMP policy to verify that hosts allowed access to the fabric through SNMP read
operations are included in the RSNMP policy. If the host is allowed access to the fabric but is
not included in the RSNMP policy, add the host to the policy.
If the host is not allowed access to the fabric, this is a valid violation message and an
unauthorized entity is trying to access your fabric. Take appropriate action as defined by your
enterprise security policy.
Severity
INFO
126
Fabric OS 3.x Document Addendum

Advertisement

Table of Contents
loading

Table of Contents