HP StorageWorks 2/16 - SAN Switch Manual page 107

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

Severity
CRITICAL
DIAG-STATS (FRX)
Message
<timestamp>
CRITICAL DIAG-STATS (FRX), 1, <test name>, pass <number>,
Pt<port info> FramesRx Counter Wrong, is <actual value> sb <expected
value>,
Err# <error code>
Probable Cause
The port counter value did not match the number of frames actually transmitted. In this case,
FramesRx equals the number of frames received. This can be caused by a faulty cable or
deteriorated SFP. It can also indicate more serious problems in the motherboard or ASIC. This
message is generated by the portloopbacktest command. The error code value is
for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
Fabric OS 3.x Document Addendum
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Diagnostic and system error messages reference guide
107

Advertisement

Table of Contents
loading

Table of Contents