HP StorageWorks 2/16 - SAN Switch Manual page 95

Hp storageworks fabric os 3.x document addendum (aa-rw24a-te, january 2005)
Hide thumbs Also See for StorageWorks 2/16 - SAN Switch:
Table of Contents

Advertisement

DIAG-ERRSTAT (TRUNC)
Message
<timestamp>
CRITICAL DIAG-ERRSTAT (TRUNC), 1, <test name>, pass <number>,
Pt<port information> TruncFrm Error Counter is <number> sb 0,
Err# <error code>
Probable Cause
The Port Error Statistics counter is nonzero, which means that a Truncated frame error
was detected when receiving frames. This can be caused by a faulty cable or deteriorated SFP.
It can also indicate more serious problems in the motherboard or ASIC. This message is
generated by the portloopbacktest or spinsilk command. The error code value
is for internal use only.
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
DIAG-INIT
Message
<timestamp>
CRITICAL DIAG-INIT, 1, <test name>, pass <number>,
Pt<port information><speed> Failed to go active after initialization,
Err# <error code>
Probable Cause
The port failed to go active in the loopback mode requested. This can be caused by a faulty
cable or deteriorated SFP. It can also indicate more serious problems in the motherboard or
ASIC. This message is generated by the crossporttest, portloopbacktest, or
spinsilk command. The error code value is for internal use only.
Fabric OS 3.x Document Addendum
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Diagnostic and system error messages reference guide
95

Advertisement

Table of Contents
loading

Table of Contents