Diagnostic and system error messages reference guide
Recommended Action
Check for a faulty cable or deteriorated SFP. Replace the cable or SFP if necessary. If the
problem persists:
Severity
CRITICAL
DIAG-INTNIL
Message
<timestamp>
CRITICAL DIAG-INTNIL, 1, <test name>, pass <number>,
Pt<port information> Failed to get CMI Error (interrupt),
Err# <error code>
Probable Cause
The ASIC failed to get a CMI error (interrupt). This usually indicates an ASIC failure. This
message is generated by the cmitest command. The error code value is for internal use
only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-INTNOTCLR
Message
<timestamp>
CRITICAL DIAG-INTNOTCLR, 1, <test name>, pass <number>,
Pt<port information> Offs <offset value> CMEM_ERR int bit could not be
cleared,
Err# <error code>
96
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.