DIAG-MEMSZ
Message
<timestamp>
CRITICAL DIAG-MEMSZ, 1, <test name>,
Memory size to test <= 0,
memFindMax = <max mem size> and N_UNTESTED_RAM = <number>,
Err# <error code>
Probable Cause
The memory size to be tested is less than or equal to 0. This usually indicates a motherboard
failure. This message is generated by the ramtest command. The error code value is for
internal use only.
Recommended Action
For the SAN Switch 2/16, replace the motherboard FRU.
For the SAN Switch 2/8 EL, replace the entire switch.
Severity
CRITICAL
DIAG-NOSEGMENT
Message
<timestamp>
CRITICAL DIAG-NOSEGMENT, 1, <test name>,
Pt<port info><speed> Failed to segment,
Please check cables,
Err# <error code>
Probable Cause
The port failed to go into loopback mode. This message usually indicates improper cable
connections. This message is generated by the spinsilk command. The error code
value is for internal use only.
Recommended Action
Verify cable connections. Reseat the SFPs and cables and then reexecute the test. Check for a
faulty cable or deteriorated SFP. Replace the cable or SFP if necessary.
Fabric OS 3.x Document Addendum